The Silent Brick Single Drive

The device may only be opened by specialized personnel.

The device must be connected to a socket with earth contact.

Ensure easy access to the power outlets.

Caution, risk of electric shock: To disconnect the power supply, all power sources must be disconnected to avoid the risk of electric shock.

Block Image

Caution, risk of electric shock

Block Image

The Single Drive is the smallest Silent Brick System. The Single Drive includes a control unit for the Silent Brick Library, a slot (13) for Silent Brick Storage Containers, as well as two power supplies (16) for energy supply and is not expandable via Shelf.

On the front side of the device, there are three light emitting diodes (10). These indicate the status of the device as follows:

  • Green: The system is active.

  • Yellow: The system is in standby mode.

  • Red: The system has detected an error (This LED lights up in addition to the operating state).

Block Image

Fig.: Drive Front Side

No.

Designation

10

Operating State Display

13

Slot for Silent Bricks

Block Image

Fig.: Single Drive Back

No.

Designation

16

Power Supply

20

Management Connection (1GB Ethernet RJ45)

25

Data connection (1GB Ethernet)

28

Fan

29

Power

30

Emergency Release of Slots for Silent Bricks