Troubleshooting Table
Silent Brick Controller of the X Series
|
Symptom |
Cause |
Resolution |
|
The controller cannot be powered on. |
The power supply has not been properly inserted. |
Insert the power supply into the respective slot of the controller until it locks into place. |
|
The system does not detect the Silent Brick Pro. |
The Brick was not inserted far enough. |
Ensure that the Silent Brick Pro is flush with the front of the controller. Appropriate pressure is required when inserting it. |
|
The controller does not eject the Brick. |
The Brick is in use. |
When used as VTL, export the Silent Brick to the Export Slot using the backup software.
|
|
The configuration interface is not accessible. |
The wiring may be faulty. |
Verify the system's accessibility using “Ping” and correct the wiring if necessary. |
|
The SAN approval via iSCSI cannot be found. |
The data port may not be accessible. |
Verify the system's accessibility using “Ping” and correct the wiring if necessary. |
|
The speed does not match the expected value. |
The network speed may not be consistently available. |
Switch to the service area and use the tool iPerf to perform a performance test durchzuführen. |